SW51 No. 6, No. 7 Inhibited to use.
SW51 No. 8 SDT signal detection
Used to set whether SDT signal which is the second dial tone when
transmitting to F net is detected or not.
When the SDT signal is not detected, dial is made normally even after
"16×."
When set to 1, the signal is detected.
When set to 0, the signal is not detected.
Default: 0 (Not detected)
SW52 No.1, No.2 DT/BT detection frequency range
Used to set the DT/BT detection frequency range.
Default: 0 1 (420Hz to 680Hz)
SW52 No. 3 Busy tone detection level table
Used to set the busy tone detection level table.
Default: 0 (constant (ROM))
SW52 No.4, No.5 Busy tone detection level
Used to set the lowest detection level when detecting busy tone.
When set to 0 0, busy tone of –43dB is detected.
When set to 0 1, busy tone of –35dB is detected.
When set to 1 0, busy tone of –33dB is detected.
When set to 1 1, busy tone of –30dB is detected.
This setting is made when busy tone is erroneously detected.
Default: 0 0 (–43dB)
SW52 No.6–No.8 Inhibited to use.
SW53 No.1–No.8 Inhibited to use.
SW54 No.1–No.8 Inhibited to use.
SW55 No.1–No.8 Inhibited to use.
SW56 No.1–No.8 Inhibited to use.
SW57 No.1–No.8 Inhibited to use.
SW58 No.1, No.2 Inhibited to use.
SW58 No.3–No.8 External connection sound volume
Used to set External connection sound volume.
The set range is 0 (0.0dBm) to 48 (–24.0dBm) in the increment of
0.5dBm by binary input.
When set to 49 or greater, the setup value comes as below.
49=–28.0dBm 50=–32.0dBm 51=–36.0dBm 52=–40.0dBm
53=–48.0dBm 54=–56.0dBm 55=–63.0dBm 56 = – ∞ infinite (mute)
Default: –10.0dBm
SW59 No.1–No.4 Signal send level Max.
Used to set Signal send level Max.
The set range is 0 (0dBm) to 15 (–15dBm) in the increment of 1dBm by
binary input.
Default: –6dBm
SW59 No.5, No.6 Transmission cable amplitude equalizer
Used to set Transmission cable amplitude equalizer.
Default: 0 0 (0dB)
SW59 No.7, No.8 Reception cable amplitude equalizer
Used to set Reception cable amplitude equalizer.
Default: 0 0 (0dB)
SW60 No.1, No.2 Reception SED ON level
Used to set Reception SED ON level.
Default: 1 1 (–48dB)
SW60 No. 3 Inhibited to use.
SW60 No.4–No.8 Reception gain adjustment
Used to set Reception gain adjustment.
The set range is 0 (+6.0dBm) to 24 (–6.0dBm) in the increment of
0.5dBm by binary input.
Default: 0.0dBm
SW61 No. 1–No.8 Inhibited to use.
SW62 No.1–No.8 Inhibited to use.
SW63 No.1–No.8 Inhibited to use.
SW64 No.1–No.3 Inhibited to use.
SW64 No.4–No.8 DTMF send level (high level)
Used to set the DTMF signal send level (high group).
0 (0.0dBm) to 21 (–21.0dBm) in the increment of 1dBm
Default: –6dBm
SW65 No.1–No.4 Maximum DTMF send level
Used to set the maximum send level in DTMF signal send.
Setup is made in the range of 0 (0.0dBm) to 15 (–15.0dBm) by binary
input.
The setup is made in the increment of 1dB.
Default: 0dBm
SW65 No.5–No.8 DTMF send level (difference between
high and low level)
Used to set the DTMF signal send level (low group).
0 (–2.0dBm) to 15 (+5.5dBm) in the increment of 0.5dBm
Default: +2.0dBm
SW66 No. 1 Default date, sender print
Used to set whether the registered sender information and date and
time of transmission are printed at the top of the transmission docu-
ment when a document is transmitted through the second line.
When set to 1, date and sender are printed.
When set to 0, date and sender are not printed.
Default: 1 (Date and sender are printed)
SW66 No. 2 Department number notification
Used to set whether the department number is transmitted as sender
information when the department management function is enabled.
Default: 0 (OFF)
SW66 No. 3 Date and sender print position setup
Used to set the print position of date and transmitter information on the
transmitted documents.
When set to 1, added upper inside the document.
When set to 0, added outside the document.
Default: 0 (Added outside the document)
SW66 No. 4, No. 5 Inhibited to use.
SW66 No.6–No.8 Polarity reversion settlement time
Used to set Polarity reversion settlement time.
Setup is made in the range of 200ms – 1600ms by binary input.
Default: 200ms
SW67 No.1–No.4 After sending CFR, double wait is
inhibited for 1.6sec.
Used to set that the double wait is inhibited for 1.6sec. after sending
CFR.
Setup is made in the range of 0ms – 3000ms by binary input.
Default: 1600ms
SW67 No. 5 Measurement of communication time (image)
Used to set YES/NO of measurement.
Used to measure the communication time in phase C. However, it is
the communication time in the latest phase C. (Unit: msec)
Default: 1 (YES)