Sharp AR-FX7 Service Manual page 76

Digital multifunctional system option
Hide thumbs Also See for AR-FX7:
Table of Contents

Advertisement

2. Communication result code
Described on the communication report table, the communication man-
agement table, and the protocol communication report table when
communication is completed.
A. Composition of communication report code
Communication result X X (X X X X)
Upper 2 digits of a communication result code: Communication report
code of 00 - 90 (Refer to the list of communication report codes.)
Lower 4 digits of a communication result code: Codes used by service-
man.
Top 2 digits
Communication report sub code 1 (Refer to
the list of communication sub code 1.)
Bottom 2 digits
Communication report sub code 2 (Refer to
the list of communication sub code 2.)
Note) Communication report sub code 1 and sub code 2 are in hexa-
decimal. (The others are in decimal.)
<Communication result code list>
Result
Final reception signal
code
(Transmitting side)
0
Abnormal signal
1
NSF, DIS
2
CFR
3
FTT
4
MCF
5
PIP, PIN
6
RTN, RTP
7
No signal, DCN
8
PPR
9
10
11
RNR
12
CTR
13
ERR
14
15
16
Abnormal signal
17
NSF, DIS
18
CFR
19
FTT
20
MCF
21
PIP, PIN
22
RTN, RTP
23
No signal, DCN
24
PPR
25
RNR
26
CTR
27
ERR
28
29
V.8 Phase-1
30
V.8 Phase-2
31
V.8 Phase-3
(Note) For result codes 16 - 31, V.34 mode communication.
For 32 or later, refer to the table below.
<Communication result code list>
Result code
Communication
(Communication
report result
result)
column
0 – 31
Refer to the
previous table.
33
Busy
Final reception signal
(Receiving side)
Abnormal signal
(SID), (SUB), NSS, DCS
(PWD), (SEP), NSC, DTC
EOP
EOM
MPS
PRI-Q
DCN
PPS-EOP
PPS-EOM
PPS-MPS, PPS-NULL
RR
CTC
EOR-Q
PPS-PRI-Q
Abnormal signal
SID, SUB, NSS, DCS
PWD, SEP, NSC, DTC
PPS-EOP
PPS-EOM
PPS-MPS, PPS-NULL
PRI-Q
DCN
RR
CTC
EOR-Q
PPS-PRI-Q
V.8 Phase-1
V.8 Phase-2
V.8 Phase-3
Communication interruption
content
Depends on the
communication disconnection
position. For 16 or later, V.34
mode communication.
The calling side cannot
connect the line with the other
party.
AR-FX7 TROUBLE CODE LIST 10 - 2
Result code
Communication
(Communication
report result
result)
column
34
Cancel
35
Power OFF
38
Reception
memory over
42
Reception
length over
44
Document error
46
No response
from the other
party
48
OK
49
The other party
has no polling
function.
50
Polling is not
accepted.
51
Polling allow
number
discrepancy
56
Interface not
accepted
59
The other party
has no function
of F code
bulletin board.
60
F code polling
is not accepted.
61
F code bulletin
board number
discrepancy
Communication interruption
content
When a communication
interruption command is
delivered during transmission
or reception, <Send/Receive/
Poll/Bulletin>
When the operation is
interrupted by the stop key.
When the power is cur off
during sending or receiving,
<Send/Receive/Poll/Bulletin>
When memory is over during
reception, <Receive/Poll>.
When printing cannot be
performed during reception
due to inhibition of proxy
reception, <Receive/Poll>
When the received data length
of one page exceeds the range
during reception, <Receive/Poll>
When a document jam occurs
during direct transmission,
<Send>
When the FAX signal from the
other party is not detected
within T1 time, <Send/Poll>
Communication normal end
When the called side has no
polling function in polling
reception, <Poll>
When the called side has no
transmission data, <Bulletin>
When DCN is received for DTC
in polling reception, <Poll>
When there is no transmission
data in polling transmission,
<Bulletin>
When the allow number does
not coincide in polling
transmission, <Bulletin>
When the system number does
not coincide in polling
transmission, <Bulletin>
1) When DCN is received for
NSS in transmission of the
relay instruction, <Send>
2) When a receiving station
number that is not
registered is instructed in
reception of the relay
instruction, <Receive>
3) When F code relay
instruction is received
during F code relay
broadcasting, <Receive>
When the other party machine
does not have DIS bit 47
(Selective polling function) in F
code polling (ringing), <Poll>
When DCN is received for SEP
in F code polling (ringing), <Poll>
When there is no transmission
data for SEP in bulletin board,
<Bulletin>
When the sub address (bulletin
board number (SEP)) does not
coincide in bulletin board,
<Bulletin>

Advertisement

Table of Contents
loading

Table of Contents