SW35 No. 1 Automatic reduction print
Used to set whether the received document is automatically reduced
and printed so that the print-out is fit in a fixed size when the document
size is longer than the fixed sizes but smaller than the max. length of
automatic reduction ratio.
When set to 1, the document is printed with automatic reduction.
When set to 0, the document is printed without reduction.
Default: 1 (Automatic reduction print enable)
SW35 No. 2 Paper selection priority
Used to set whether the FAX reception paper is selected by data width
priority or data area priority.
"1": Width priority
"0": Area priority
Default: 0 (area priority)
SW35 No.3, No.4 Output condition setup
Used to set whether the received data are reduced or divided to print
when a document is received and there is no suitable size paper.
bit
3 4
0 0
: Reduction allowed
0 1
: AB
1 0
: Division allowed
1 1
: A
Default: 0 0 (Reduction print)
SW35 No.5–No.8 Automatic reduction rate setup
Used to set the length of a received document which can be automati-
cally reduced and printed on paper longer than the fixed sizes when
automatic reduction print is allowed.
Setup is made in the range of 0 – 15% by binary input of N in "100% –
N × 1%."
Default: 94% (6% reduction)
SW36 No.1–No.4 Waiting time for PC-FAX job end
Used to set the waiting time for PC-FAX job end.
The set range is 0 (32 min) to 15 (2 min) in the increment of 2 min by
binary input.
Default: 2 min.
SW36 No.5, No.6 Inhibited to use.
SW36 No.7, No.8 Waiting time for lift-up
Used to set the wait time before starting printing when the cassette is
being lift up in print ready state.
Default: 0 0 (30 sec)
SW37 No. 1 Thin paper setup
Used to set whether the thin paper use is allowed or not.
Default: 0 (Inhibited)
SW37 No. 2 Specification of 1m scan when there is no line
send setting
Used to set "Reception specification of 1m" when SW37-3 – 6 (Rota-
tion transmission selection) is set to NO.
Default: 0 (Normal operation)
SW37 No. 3 Rotation send selection (A4 → A4R)
Used to set whether A4 document is transmitted as A4 or the scanned
image is rotated and transmitted as A4R.
When set to 1, the document is transmitted as A4 width.
When set to 0, the document is transmitted as A3 width.
Default: 1 (Transmitted as A4 width)
SW37 No. 4 Rotation transmission selection (B5R → B5)
Used to set whether B5R document is transmitted as B5R or the
scanned image is rotated and transmitted as B5.
When set to 1, the document is transmitted as B4 width (B5).
When set to 0, the document is transmitted as A4 width (B5R).
Default: 1 (Transmitted as B4 width)
SW37 No. 5 Rotation transmission selection (A5R → A5)
Used to set whether A5R document is transmitted as A5R or the
scanned image is rotated and transmitted as A5.
When set to 1, the document is transmitted as A4 width (A5).
When set 0, the document is transmitted as A4 width (A5R).
(However, the transmission width is A4.)
Default: 1 (Transmitted as A4 width (A5))
SW37 No. 6 Rotation transmission selection (11 × 8.5 → → → →
8.5 × 11)
Used to set whether Letter (landscape) document is transmitted as A3
width or the scanned image is rotated and transmitted as A4R width.
Default: 1 (Rotation)
SW37 No. 7 Inhibited to use.
SW37 No. 8 Rotation scan word calculation
Used to set the rootation scan word calculation.
Default: 0 (Round down)
SW38 No. 1 Protocol monitor
Used to set whether communication protocol result is printed after
completion of communication or not.
Used for communication test.
Default: 0 (No print)
SW38 No. 2 Output only in case of an error of the protocol
monitor
Used to set whether protocol monitor is outputted only when a commu-
nication error occurs or every time when communication is completed.
Effective when SW38-1 (Protocol monitor) is set to YES. However,
only when SW38-1 is set to 1 (YES), protocol monitor is outputted in
case of a communication error.
Default: 0 (NO)
SW38 No. 3 Protocol monitor save
Used to set whether the protocol monitor of the final communication is
saved or not.
When set to "Saved," the preceding protocol monitor can be printed
with SIM 66-21.
Default: 1 (Save)
SW38 No.4, No.5 Line sound monitor range
Used to set the line sound monitor range when the line monitor func-
tion is used.
Used to set to monitor NSF signal send/receive until NSF signal is
sent/received.
When set to ALL, all procedures up to line disconnection are moni-
tored.
The setup items are as follows:
bit
4 5
0 0
0 1
1 0
1 1
Default: 0 1 (Up to NSF signal send/receive)
SW38 No. 6 Line monitor display
Used to set whether the communication speed and the reception level
are displayed on the LCD or not.
Displayed on the communication status screen by pressing the job sta-
tus key.
When set to 1, displayed on LCD.
When set to 0, not displayed on LCD.
Default: 0 (not displayed)
SW38 No. 7–No. 8 Inhibited to use.
AR-FX7 SOFT SWITCH 7 - 33
: OFF
: Until NSF signal is sent/received
: All