Sharp AR-FX7 Service Manual page 56

Digital multifunctional system option
Hide thumbs Also See for AR-FX7:
Table of Contents

Advertisement

SW10 No. 8 Send request protection
Used to set YES/NO of the confidential protection function (inhibition of
transmission to an erroneous party). Confidential protection is per-
formed by collating the number registered in this machine and that in
the other party's machine. (Sender's telephone number ↔ Send
request allow number, System number ↔ ID number)
When set to 1, protection is not made.
When set to 0, protection is made.
Default: 0 (Protection)
SW11 No. 1, No. 2 Inhibited to use.
SW11 No. 3 Sender's telephone number registration
Used to set whether the registered sender's TEL No. can be changed
or not.
When set to 1, sender's TEL No. cannot be registered and changed.
To prevent sender's TEL No. from being changed erroneously, this is
set to 1.
Default: 0 (Enabled)
SW11 No. 4 Yes/No of manual send selection menu
display
Used to set whether the manual transmission selection screen is dis-
played or not.
Default: 1 (displayed)
SW11 No.5–No.8 Inhibited to use.
SW12 No. 1 Direct send recall Allow/Inhibit
Used to set Allow/Inhibit of direct send recall.
Default: 0 (Inhibited)
SW12 No.2 Manual/Auto reception auto swiching
(Inhibited except for France.)
Used to set whether automatic reception is made or not when ringing is
made the number of auto switch call times in manual reception.
Default: 0 (Inhibited)
SW12 No.3–No.6 Number of auto switch calls of manual
reception → → → → auto reception (Inhibited except for France.)
When the above setup is allowed, automatic reception is made at the
set number of times.
The set range is 1 to 9 times.
Default: 9 times
SW12 No.7 Inhibited to use.
SW12 No.8 Remote selection models
Used to set remote selection models.
Default: 0 (Call-in only)
SW13 No.1–No.4 Recall times in busy
Used to set the number of recall times in case of busy state of the other
party or when call does not reach the other party.
Setup is made in the range of 0 – 10 times by binary input.
When set to 0, recall is not made.
Default: 2 times of recall
SW13 No.5–No.8 Recall interval in busy
Used to set recall interval after disconnection due to the busy state of
the other party or no response.
The set range is 1 to 15 min in the increment of 1 min by binary input.
When set to 0, it is the same as setup of 3 min.
Default: 3 min
SW14 No.1–No.4 Recall number in case of a transmission
error
Used to set the number of recall times in case of a communication
error.
Setup is made in the range of 0 – 5 times by binary input.
When set to 0, recall is not made.
Default: 1 time of recall
SW14 No.5–No.8 Recall interval in communication error
Used to set recall interval after disconnection of communication due to
a communication error in memory transmission.
The set range is 0 to 15 min in the increment of 1 min by binary input.
When set to 0, recall is made immediately after disconnection.
However, the time interval set by SW41-5–8 (Interval between the end
of a communication and the next call) is taken.
Default: 1 min
SW15 No. 1 – No.3 Inhibited to use.
SW15 No.4–No.8 Signal send level
Used to set the attenuation quantity of signal send level from the
modem.
0 (0dBm) to 26 (–26dBm)
Default: –8dBm
SW16 No.1–No.4 Modem speed (V.33 mode or less)
Used to set the speed to start communication. When communication
troubles occur frequently, the speed may be reduced to solve the trou-
bles.
Default: 1 0 0 0 (V.17 14.4kbps)
SW16 No.5, No.6 Modem speed in reception fixed
Used to set the start speed of reception procedure when receiving from
the other party other than V.34.
bit
5 6
0 0
0 1
1 0
1 1
When set to "no fixing," the operations are the same as V.17-
14400BPS.
The above four setups are possible. The reception procedure is started
at the set communication speed.
Default: 0 0 (no fixing) Reception is made at the proper communication
speed.
SW16 No. 7 EOL detection timer
Used to set the detection timer of EOL (End Of Life) when Phase-C
reception.
When set to 1, the timer is set to 25sec.
When set to 0, the timer is set to 13sec.
Default: 0 (13 sec)
SW16 No. 8 RTN EOL send times
Used to set the RTN EOL send times.
Default: 1 (6 times)
SW17 No. 1 Inhibited to use.
SW17 No. 2 MH fixed (except for SG3)
Used to set whether the encoding system is fixed to MH or not in a
mode other than SG3 communication.
When set to 1, the encoding system is fixed to MH.
When set to 0, the encoding system is not fixed to MH.
Default: 0 (The encoding system is not fixed to MH.)
AR-FX7 SOFT SWITCH 7 - 29
: No fixing
: V.29-9600BPS
: V.27ter-4800BPS
: V.17-14400BPS