WARNING
Properly install and insulate the drain piping to ensure water
is drained away properly.
Improper installation can cause water to leak, generating a slippery
surface that risks physical injury .
CAUTION
Be very careful when transporting the product. There is a risk of the product falling and causing physical injury.
• Use appropriate moving equipment (forklift, spreader bar, etc.) to transport each chiller; ensure the equipment is of the correct material and
capable of supporting the weights listed.
• Some products use polypropylene bands for packaging.
• Support the chiller at specified positions to avoid slipping out of the rigging apparatus. Ensure that the load of the chiller is evenly distribut-
ed and level during the move.
Do not touch the heat exchanger fins during transport; there is a risk of physical injury.
The Limited Warranty will be null and void, and LG Electron-
ics will not be responsible and will have no liability to any
customer or third party to the extent any of the following oc-
cur: acts, omissions, and conduct of any and all third parties
including, but not limited to, the installing contractor and any
repairs, service or maintenance by unauthorized or unquali-
fied personnel.
The information contained in the manual is intended for use by
a qualified service technician familiar with safety procedures
and equipped with the proper tools and test instruments.
Failure to carefully read and follow all instructions in this manual can
result in equipment malfunction, and / or property damage.
Do not install the chiller where it is exposed directly to
ocean winds.
Sea salt in the air will cause the product to corrode. Corrosion, par-
ticularly on the condenser and evaporator fins, could cause product
malfunction or inefficient operation.
Do not install the chiller where there is an obstruction
immediately above the unit. See installation clearances in
this manual.
If there is an obstruction immediately above the chiller, it can deflect the
discharge air, where it can be re-circulated into the condenser coil inlet,
causing operation malfunction.
Properly install and insulate the drain piping to ensure water
is drained away properly.
Improper installation can cause water to leak, causing a slippery surface
condition and / or water damage.
Always check for system refrigerant leaks after the unit has
been installed or serviced.
Low refrigerant levels will cause product failure.
Do not make refrigerant substitutions. Use only the refrig-
erant specified in this manual.
If a different refrigerant is used, or air mixes with original refrigerant, the
unit will malfunction and damage will occur.
Do not use polypropylene bands to lift the unit.
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
SAFETY PRECAUTIONS
Install the unit considering the potential for strong winds or
earthquakes.
Improper installation will cause the unit to fall over, resulting in physical
injury or death.
Do not store or use flammable gas/ combustibles near the
unit.
There is a risk of product failure.
Do not install the chiller in an environment with oil, steam,
sulfuric smoke, etc.
There is risk of a reduction in performance, malfunction, and / or product
damage.
Keep the chiller level / upright during installation to avoid
vibration and / or water leaks.
When installing the chiller near a hospital, mechanical room,
or similar electromagnetic field (EMF) sensitive environment,
provide sufficient protection against electrical noise.
Inverter equipment, power generators, high-frequency medical equip-
ment or radio communication equipment will cause the chiller to operate
improperly. The chiller will also affect such equipment by creating electri-
cal noise that disturbs medical treatment or image broadcasting.
Do not touch the heat exchanger fins; there is a risk of
product damage and malfunction.
When connecting refrigerant piping, remember to allow for
pipe expansion.
Improper piping installation will cause system malfunction.
Do not install the chiller in a noise-sensitive area, or
where hot air could damage surrounding structures.
Install the chiller in a safe location where no one can step on
or fall onto it.
Do not install the unit on a defective stand.
There is a risk of unit and property damage.
Install the drain hose to ensure adequate drainage.
There is a risk of water leakage and property damage.