Siemens FUJI-Reader CR-IR347 Service Manual page 291

Hide thumbs Also See for FUJI-Reader CR-IR347:
Table of Contents

Advertisement

I Installation procedure
N NOTES N
• When uncovering the new polygon assembly, release the cover claws and exercise
care not to touch the polygon mirror surface.
• Press the polygon and its spacer in the direction of the arrow shown below, and then
screw them down.
• When installing the polygon, orient it properly. When it is viewed from above, the
narrower edge should face forward.
Accomplish installation by reversing the removal procedure.
I Check procedure
(1) Turn ON the high-voltage switch (S1) on the SCN08D board.
(2) Install all covers.
(3) Turn ON the machine.
Verify that the machine starts up normally.
(4) Check for image problems.
"9.3 Checking for Image Problems"
009-058-00
10.20.2000 FM2732 (2)
Cover
New polygon assembly
(Handle carefully.)
Polygon mirror surface
Polygon mounting direction
Polygon
mirror
surface
CR-IR347 Service Manual
Claws
FR1H1405.EPS
Cable
Ensure that the
F
narrower edge is
R
O
oriented as shown.
N
T
FR7H3712.EPS
MC - 272