Functions
3-3 Lockout Release Function (Common for all cables)
This function releases the device from the lockout state and returns it to normal operation.
When in the lockout state, the device is returned to normal operation by removing the cause of
the lockout, performing lockout release: [open the output polarity setting / lockout release input
wire (pale blue) that was short-circuited, and then short-circuit within approx. 150ms to 4 sec.].
<Timing chart>
Output polarity
Open
setting / lockout
Shorted
release
Normal
Operation
Lockout
<Using PNP output>
(Brown)
(Pale blue)
(Blue)
*Switch S1
● Output polarity setting / Lockout release input
0 to +2.5V (source current 5mA or less):
102
150ms to 4 sec.
*S1
Short circuit
2 sec. or less
<Using NPN output>
(Brown)
(Pale blue)
(Blue)
*Switch S2
● Output polarity setting / Lockout release input
Vs to Vs − 2.5V (sink current 5mA or less):
Note: Vs is the supply voltage.