Introduction
When using this device, configure a control system satisfying the following requirements to estab-
lish a system-wide safety.
To use in Category 4 or 3
● To prevent the loss of the safety function due to a single fault.
Be sure to use control output (OSSD 1 / 2) of two systems.
● To prevent the loss of the safety function due to accumulation of faults.
Configure a control system that can monitor the control output (OSSD 1 / 2) and stop the de-
vice if discrepancy is detected.
<Example of inconsistence detection method>
(Example 1)
Use of relay unit and controller for light curtain
(Example 2) Monitoring of control outputs (OSSD 1 / 2) with the safety PLC.
(Example 3)
Monitoring of contact welding when safety relay is used
To use in Category 2
When using the control output (OSSD) of only one system, connect auxiliary output to PLC, etc.,
to monitor the operation of this device. In this case, configure a control system that stops the de-
vice when discrepancy between control output (OSSD) and auxiliary output is detected. In place
of the auxiliary output, control output (OSSD) of one more system is available.

1-3 Confirmation of Packed Objects

□ Main body: emitter and receiver
□ Test Rod
SF4D-F□: SF4B-TR14 (ø14 × 220mm), SF4D-H□: SF4B-TR25 (ø25 × 220mm)
□ Quick Instruction Manual (Japanese, English, Chinese, Korean)
□ General Information for Safety, Compliance, and Instructions (23 languages)
12
© Panasonic Industrial Devices SUNX Co., Ltd. 2016
One for each
1 piece
1 pc. for each language
1 pc.