Floating Blanking Function - Panasonic WUME-SF4D-2 Instruction Manual

Safety light curtain type 4
Table of Contents

Advertisement

3-11-2 Floating Blanking Function

● When the floating blanking function is used, the minimum sensing object becomes larger, and
the safe distance also becomes longer. Recalculate the safe distance and install the device ac-
cordingly.
● When the minimum number of beam axes is zero, use the interlock function as required by IEC
62046. When the minimum number of beam axes is zero, the control output (OSSD 1 / 2) turns
ON even there are no obstacles in the sensing area.
This floating function prevents the control output (OSSD 1 / 2) from turning OFF when the num-
ber of blocked beam axes is equal to or less than the set number of beam axes. Use the func-
tion when there is a moving obstacle in the sensing area.
Item
Floating blanking beam
axis setting
Floating blanking num-
ber of beam axes set-
ting
Floating blanking both
end beam axes setting
Selections for the floating blanking number of beam axes setting are 0 to 5.
The condition for the control output (OSSD 1 / 2) turning OFF is when the number of blocked
beam axes is over the maximum number of beam axes, or is under the minimum number of
beam axes.
You can specify a valid area (number of valid beam axes number).
You can validate or invalidate the floating blanking function for both end beam axes.
You can have the control output (OSSD 1 / 2) turn ON only when a number of contiguous beam
axes within the set beam axes are blocked.
When the floating blanking function is used, the digital indicator remains OFF when there is a
blocking object in the sensing area, regardless of the intensity of light received.
The minimum sensing object varies depending on the number of set beam axes.
<Minimum sensing object>
0 beam channels 1 beam channel 2 beam channels 3 beam channels 4 beam channels 5 beam channels
SF4D-F□
SF4D-H□
SF4D-A□
© Panasonic Industrial Devices SUNX Co., Ltd. 2016
Description
You can change the beam axis
that is invalid.
You can change the number of
beam axes that are invalid.
You can validate or invalidate
the floating blanking function for
both end beam axes.
Not set
ø14mm
ø24mm
ø25mm
ø45mm
ø45mm
ø85mm
WARNING
Settings / ranges
Zero beam axes (floating blank-
ing function invalid)
Any number of beam axes (1 or
more)
Any number of beam axes
• Maximum: 1 to 5 beam axes
• Minimum: 0 to 5 beam axes
Valid (Floating blanking function
can be set)
Invalid (Floating blanking func-
tion cannot be set)

Floating blanking function

Setting (maximum number of beam channels)
ø34mm
ø44mm
ø65mm
ø85mm
ø125mm
ø165mm
Functions
Factory default
setting
0 beam axes
(Invalid)
ø54mm
ø64mm
ø105mm
ø125mm
ø205mm
ø245mm