Operation Test - Panasonic WUME-SF4D-2 Instruction Manual

Safety light curtain type 4
Table of Contents

Advertisement

Adjustment

2-6-2 Operation Test

Step 1 Supply power to the device.
Step 2 When the device starts, "
lights up in yellow on the digital indicator.
Step 3 Make sure that the digital indicators on the emitter and receiver are OFF.
If a yellow number blinks or lights in the digital indicator, refer to "Chapter 5 Trouble-
shooting" and inform your technician.
Step 4 Move the test rod (ø14mm for SF4D-F□, ø25mm for SF4D-H□, ø45mm for SF4D-A□) up
and down directly in front of the emitter (A), midway between the emitter and the receiver
(B), and directly in front of the receiver (C) (3 positions) at a speed of 1,600mm/sec. or less.
Emitter
Step 5 While moving the test rod in Step 4, verify that the control output (OSSD 1 / 2) is OFF
while the test rod is in the sensing area. In addition, verify that the OSSD indicator of
the receiver and the operation indicator of the emitter both light red.
If the operation of the control output (OSSD 1 / 2) and the indicators of the emitter and
receiver do not match the movement of the test rod, refer to "Chapter 5 Trouble-
shooting" and inform your technician.
<Reference>
If an indicator indicates the light-received state when the test rod blocks light, make sure there are
no reflective objects or scattered light in the vicinity.
80
" (when PNP output is set) or "
(B)
(A)
(C)
© Panasonic Industrial Devices SUNX Co., Ltd. 2016
" (when NPN output is set)
Receiver
Test rod