Panasonic WUME-SF4D-2 Instruction Manual page 124

Safety light curtain type 4
Table of Contents

Advertisement

Functions
■Changing the muting sensor output setting
The muting sensor output setting can be changed to NONC (Normally Open / Normally Closed)
to validate operation even when there is no input time difference.
<NONO [Normally Open / Normally Open (factory default setting)]>
Auxiliary output
NO (Normally Open) type
ON when light not received (photo-
electric sensor, etc.)
ON when object approaches (proxim-
ity sensor, etc.)
ON when contact occurs (position
switch, etc.)
<NONC [Normally Open / Normally Closed]>
Auxiliary output
NO (Normally Open) type
ON when light not received (photo-
electric sensor, etc.)
ON when object approaches (proxim-
ity sensor, etc.)
ON when contact occurs (position
switch, etc.)
NC (Normally Closed) type
ON when light received (photoelectric
sensor, etc.)
ON when object moves away (prox-
imity sensor, etc.)
ON when contact does not occur (posi-
tion switch, etc.)
■Exit-only muting function
When the exit-only muting function is used, a muting sensor is only installed on the danger zone
side. There is no need for installation on the safe zone side. The conditions required for the exit-
only muting function are described below.
<Installation conditions for exit-only muting>
● The detected object must move from the danger zone to the safe zone.
● One-way movement only.
● The detected object must pass through the sensing area within 4 seconds after muting sen-
sor 1 or 2 turns OFF.
<Start conditions for muting>
Same.
<Release conditions for muting>
The following release conditions change when exit-only muting is used.
● Blocking continues even after an elapse of 4 seconds after muting input A or B is OFF at ap-
prox. 20ms or more.
● When the device changes to the light receiving state.
124
Input time
Muting input
difference
0.03 to 3 sec.
A, B
*Can be changed
Input time
Muting input
difference
A
0 to 3 sec.
(Simultaneous
input possible)
*Can be changed
B
© Panasonic Industrial Devices SUNX Co., Ltd. 2016
Operation
Operation
when ON
when OFF
0V or +V
Open
Operation
Operation
when ON
when OFF
0V or +V
Open