Panasonic WUME-SF4D-2 Instruction Manual page 145

Safety light curtain type 4
Table of Contents

Advertisement

<Response time by number of beam channels>
Control output (OSSD 1 / 2)
Number of units in
series connection
Number of units in
parallel connection
4 to 48
49 to 96
107 to 127
128 to 144
145 to 192
193 to 256
© Panasonic Industrial Devices SUNX Co., Ltd. 2016
Main sensor
1 unit 2 units 3 units 4 units 0 unit 0 unit 1 unit 1 unit 2 units 2 units 3 units
1 unit
0 unit 0 unit 0 unit 0 unit 1 unit 2 units 1 unit 2 units 1 unit 2 units 1 unit
6ms
10ms 10ms 12ms 12ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms
8ms
10ms 10ms 12ms 12ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms
10ms
12ms 12ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms
12ms 12ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms
14ms 14ms 16ms 16ms 14ms 14ms
16ms 16ms 18ms 18ms
Response time (OFF response)
Sub sensor
Specifications
145

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sf4d series

Table of Contents