Mitsubishi Electric MELSEC iQ-F Series User Manual page 159

Hide thumbs Also See for MELSEC iQ-F Series:
Table of Contents

Advertisement

Diagnostic information 2
■Diagnostic information 2 (Un\G4144 to Un\G4159)
When Diagnostic information 2 is valid (1 is stored in b8 to b15 of 'Diagnostic information status flag' (Un\G4128)), the
manufacturer code, model code, device version, module information, error code, and detailed module information are stored.
When Diagnostic information 2 is invalid (0 is stored in b8 to b15 of 'Diagnostic information status flag' (Un\G4128)), 0 is
stored.
Address
Name
Un\G4144
Manufacturer code
Un\G4145
System area
Un\G4146
Model code
Un\G4147
Un\G4148
Device version
Un\G4149
System area
Un\G4150
Own station module information
Un\G4151
Error code
Un\G4152
Detailed module information
Un\G4153
Un\G4154 to
System area
Un\G4159
If the remote station specified with 'Diagnostic request information' (Un\G4127) is disconnected, the
information just before the disconnection is stored.
CCIEF Basic each status
■CCIEF Basic each status (Un\G4160)
Each status of CC-Link IE Field Network Basic is stored.
Address
Bit
Name
Un\G4160
b0
Cyclic transmission status
b1
Data link status
b2
Reserved station specification status
Diagnostic information display request
■Diagnostic information display request (Un\G4162)
The diagnostic information of the remote station that is specified by the 'Diagnostic request information' (Un\G4127) is read to
Un\G4128 to Un\G4159 after execution of the END instruction of the scan where bit 0 turns off and on.
0 is stored if the setting of the diagnostic information is completed during the END process.
Address
Bit
Name
Un\G4162
b0
Diagnostic information display request
Description
Manufacturer code of a remote station specified is stored.
Model code (lower) of a remote station specified is stored.
Model code (upper) of a remote station specified is stored.
Device version of a remote station specified is stored.
Module information of a remote station specified is stored.
Latest error code of a remote station specified is stored.
Detailed module information (lower) of a remote station specified is stored.
Detailed module information (upper) of a remote station specified is stored.
Description
This register turns on when initial process is completed. Turns off when the cyclic
transmission is stopped because of an error, etc.
• Off: Not performed
• On: Being performed
This register turns on when the 'Data link status of each station' (Un\G4104 to
Un\G4105) is on for even one station.
• Off: All stations normal
• On: One or more faulty stations
This register turns on when the 'Reserved station specification status' (Un\G4113 to
Un\G4114) is on for even one station.
• Off: Not specified
• On: Specified
Description
• Off: Diagnostic information display not requested
• On: Diagnostic information display request
APPX
Appendix 4 Buffer Memory
A
157