CC-Link IEF Basic Setting

Set the CC-Link IE Field Network Basic.
Item
Network Configuration Settings
Refresh Settings
Station-based Block Data Assurance
Network Configuration Settings
Set the network configuration.
Double-click <Detailed Setting> of the "Network Configuration Settings".
Item
[Detect Now] button
[Link Scan Setting] button
Connected Count
No.
Model Name
STA#
Station Type
RX/RY Setting
Points
Start
End
RWw/RWr Setting
Points
Start
End
Group No.
RSVD STA
Description
Set the information of the remote station to the master station. Moreover,
configure link scan settings (timeout time and number of retries for remote
station disconnection detection). ( Page 71)
Configure the settings to automatically link refresh RX/RY/RWr/RWw data
to the devices. ( Page 75)
Set whether to assure the data in station units when refreshing the link
between the host station and CPU module. This prevents the data that is
read/written for each slave is not separated into the new data and old data.
Description
Connected devices are automatically detected.
Configure link scan settings.
The total number of connected remote stations is displayed.
The station number of the remote station is displayed.
Module model name is displayed.
When there is no module information, "Module With No Profile Found" is
displayed.
The start station number of the remote station is displayed.
The station type (master station/remote station) is displayed.
Set the assignment of the number of points for RX/RY in increments of
64 points.
The start number of RX/RY is displayed.
The end number of RX/RY is displayed.
The number of points for the number of stations in increments of 32
points is displayed.
The start number of RWw/RWr is displayed.
The end number of RWw/RWr is displayed.
Set group numbers of remote stations.
Set whether to set the remote station as a reserved station.
Setting range
• Enable
• Disable
(Default: Disable)
Setting range
• 64 (1 Occupied Station)
• 128 (2 Occupied Stations)
• 192 (3 Occupied Stations)
• 256 (4 Occupied Stations)
(Default: 64 (1 Occupied Station))
1 to 2
(Default: 1)
• No Setting
• Reserved Station
(Default: No Setting)