TA B L E O F C O N T E N T S

Internal components

Label
Part
A
Maintenance cover
B
Rotary switch set current limit
C
Nano-M2M SIM card slot
D
Primary Ethernet port RJ45
E
Secondary Ethernet port RJ45
F
Configurable output contact
G
Configurable input contact
H
Modbus RTU (RS-485)
Load management
Load management makes sure that the available capacity of
the building or home is not exceeded. A number of devices
share a grid connection, that has a maximum capacity.
The total power demand of the devices that use the grid
connection must not exceed the grid capacity.
P R E V I O U S C H A P T E R
A
B
C
D
E
I
J
K
N E X T C H A P T E R
P
F
G
H
L
M
N
O
Label
Part
I
AC input L1
J
AC input L2
K
AC input PE
L
Charge cable L1
M
Charge cable L2
N
Charge cable PE
O
Charge cable with strain relief
P
Display
The load management feature prevents that the system
exceeds the grid capacity and prevents damage of the
fuses. At times when the current demand is high, the EVSE
decreases the output of current. The current will increase
again when there is availability on the grid. Also, the load
management feature makes sure that the available load is
optimally shared.