32
TA B L E O F C O N T E N T S
—
Technical data
AC input
Charging type
Input/output power rating and current
Input/ouput voltage, frequency
Network type
Cable type / Cable storage
Protections
Ground fault circuit interrupter
Overvoltage category
Energy metering
Rotary switch set current limit options 80 A model
Rotary switch set current limit options 40 A model
Stand-by mode power consumption
Power-down backup capacitor
Noise level
≔
P R E V I O U S C H A P T E R
Mode 3 charging, level 2
9.6 kW / 40 A, 19.2 kW / 80 A
208 / 240 Vac, 50 / 60 Hz
TT, TN
SAE J1772, type 1 cable, 25 ft (7.6 m). Cable is wrapped around charger and front holster inlet
Overcurrent, overvoltage, undervoltage, integrated surge protection
Integrated 20 mA AC CCID, no addiontal required
III
Revenue grade energy meter Class B (±2%)
10 A / 16 A / 24 A / 32 A / 40 A / 48 A / 56 A / 64 A / 80 A
10 A / 16 A / 24 A / 32 A / 40 A
3 W / 5.6 W with display
Able to store charge transaction during power down
Less than 40 dB (A)
←