Insert and connect the Ethernet cable
B
If your EVSE has two Ethernet connections, it is possible to
connect multiple EVSEs in a chain. Only the first EVSE is
connected to the PC, router or gateway. Only the Ethernet
E
connection is shared, there is no communication between
the EVSEs.
Procedure
1. Put the RJ45 plug (A) of the Ethernet cable in the primary
Ethernet RJ45 socket (B). Refer to section
components, page 15.
2. Connect the Ethernet cable either to a PC, router, or
A
gateway or to the previous EVSE in a chain (C).
D
3. If you connect EVSEs in a daisy chain, put the RJ45 plug
of Ethernet cable to the next EVSE (D) in the secondary
Ethernet RJ45 socket (E).
Insert the smart meter communication conduit
1. Remove the conduit enclosure plug (A) from the EVSE.
2. Put the smart meter communication conduit (B) through
the inlet hole.
3. Install the smart meter communication conduit.