Example
The following shows a procedure of aligning the synchronous position of an output axis that references the input axis.
1.
Set the following values in the synchronous control initial position parameters.
Setting item
[Pr.460] Setting method of position value per cycle after main shaft gear
[Pr.462] Cam axis position restoration object
[Pr.463] Setting method of cam reference position
[Pr.464] Setting method of cam axis position value per cycle
2.
Turn ON the target axis bit of "[Cd.381] Synchronous control analysis mode", and then turn the target axis bit from OFF
to ON in "[Cd.380] Synchronous control start" to start the synchronous control analysis mode.
3.
Verify the target axis bit is OFF for "[Cd.380] Synchronous control start", and execute positioning for the output axis to be
updated to "[Md.409] Cam axis command position value".
4.
Turn OFF the target axis bit of "[Cd.381] Synchronous control analysis mode", and then turn the target axis bit from OFF
to ON in "[Cd.380] Synchronous control start" to start synchronous control.
Setting value
2: Calculate from input axis
2: Cam axis command position value restoration
0: Previous value
2: Position value per cycle after main shaft gear
5 ADVANCED SYNCHRONOUS CONTROL INITIAL POSITION
5.4 Synchronous Control Analysis Mode
5
163