Toro Grandstand HDM 74532 Operator's Manual page 15

Table of Contents

Advertisement

Checking the Safety Interlock System
Important:
It is essential that operator safety mechanisms be connected and in proper operating
condition prior to use.
Note:
If the machine does not pass any of these tests, do not operate. Contact an Authorized Service Dealer.
Checking the Normal Engine Starting Chart
Note:
It is not necessary for the operator to be on the platform to start the engine.
State of System
*Note: The starter will crank with the PTO switch in the "ON" (pulled up) position; however, the system will
disengage the PTO and a reset PTO error will occur. Engaging the PTO will require the operator to reset the
PTO switch by turning it "OFF" (pushed down) and then turning it "ON".
Checking the Engine Starting Circuit Chart
Note:
The state of system item that is bold is being checked in each scenario.
State of System
PTO (Blades)
Disengaged
Up position, but blades
disengaged*
PTO (Blades)
Disengaged
Engaged
System
Motion Control Levers
Both levers out (neutral)
Both levers out (neutral)
System
Motion Control Levers
Both levers not in neutral
Both levers in neutral
15
Outcome
Starter should crank
Starter should crank
Outcome
Starter must not crank
Starter must not crank