HP ProLiant ML30 Gen10 Plus Maintenance And Service Manual page 84

Hide thumbs Also See for ProLiant ML30 Gen10 Plus:
Table of Contents

Advertisement

Removing and replacing an expansion card
Removing and replacing an expansion card
CAUTION:
CAUTION:
A discharge of static electricity from a finger or other conductor might damage system boards or other static-sensitive
devices. To prevent damage, observe antistatic precautions.
CAUTION:
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless all PCIe slots have either an
expansion slot cover or an expansion card installed.
CAUTION:
CAUTION:
Before replacing a DIMM, expansion card, or other similar PCA components due to a perceived hardware error, make
sure first that the component is firmly seated in the slot. Do not bend or flex circuit boards when reseating components.
Prerequisites
Prerequisites
Before you perform this procedure, make sure that you have a T-15 Torx screwdriver available.
Procedure
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following:
If the server is in tower mode, place the server on a flat, level surface with the access panel facing up.
If the server is in rack mode, remove the server from the rack .
5. Remove the access panel .
6. If installed, remove the air baffle .
HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide