Fibre Channel port specifications

NOTE
The 0
nonport side of the PowerConnect B-DCX-4S.
The temperature inside the PowerConnect B-DCX-4S can be up to 75
the internal temperature range exceeds the operating ranges of the components, the LEDs, error
messages, and Fabric Watch alerts will indicate a problem. Use the tempShow command or Fabric
Watch commands to view temperature status.

Fibre Channel port specifications

The Fibre Channel ports in the PowerConnect B-DCX-4S support full duplex link speeds at 10, 8, 4,
2, or 1 Gbps inbound and outbound, automatically negotiating to the highest common speed of all
devices connected to the port.
The ports are compatible with optical SWL (short wavelength: approximately 850 nm), optical LWL
(long wavelength: approximately 1310 nm), and Extended Long Wavelength (ELWL) laser
transmitter SFPs and XFPs (FC10-6 only) (approximately 1550 nm). The strength of the signal is
determined by the type of SFP or XFP in use.
The ports are universal and self-configuring, capable of becoming F_Ports (fabric ports), FL_Ports
(fabric loop enabled), or E_Ports (expansion ports).
The ports meet all required safety standards. For a listing of these standards, see
compliance".

Power specifications

The power subsystem is a redundant +48V DC power distribution system with a provision for up to
two 2000-watt, 48V DC bulk power supplies. Two bulk power supplies produce the intermediate
distribution voltage in the distributed power system.
The power specifications in
supplies, four FC8-48 port blades, two CP8 blades, two CR4S-8 blades, and two blower assemblies.
The use of application and/or encryption blades will consume additional power.
If the option is available, 220 VAC is recommended and a greener and more efficient alternative.
NOTE
If any of the following blades are used, 220 VAC is required:
FS8-18, FX8-24, FCOE10-24.
TABLE 20
.
Specification
Voltage
Power supply output (each)
Input frequency
90
to 40
Celsius range applies to the ambient air temperature at the air intake vents on the
Table 20

Power specifications

are calculated for fully loaded systems with two power
Value
Range: 85 - 264 VAC Auto-volt, Nominal: 100 to 240 VAC
Low line (85- 132 VAC), 1000W; High line (180 - 264 VAC), 2000W
Range: 47-63 Hz; Nominal: 50 - 60 Hz
PowerConnect B-DCX-4S Backbone Hardware Reference Manual
Celsius during operation. If
"Regulatory
53-1001808-01