Verifying Correct Configuration Of The Fabric - Dell PowerConnect B-DCX-4S Backbone Hardware Reference Manual

Hardware reference guide
Hide thumbs Also See for PowerConnect B-DCX-4S Backbone:
Table of Contents

Advertisement

5
RRP: PowerConnect B-DCX-4S chassis

Verifying correct configuration of the fabric

Copying the command outputs from this section into a file is recommended.
1. Create an "after" SAN profile by entering the following commands and copying the output to a
2. Determine any differences between the information in the "SANafter.txt" file and the
3. Resolve any issues or unintentional changes to the PowerConnect B-DCX-4S or fabric.
82
d. Organize the cables as required.
text file named "SANafter.txt":
nsShow
nsAllShow
switchShow
fabricShow
lscfg --show (if using the virtual fabric feature)
switch:admin> nsshow
Type Pid
COS
PortName NodeName TTL(sec)
N
020f00;
3;10:00:00:01:73:00:29:46;10:00:00:01:73:00:29:46; na
Fabric Port Name: 20:0f:00:60:69:90:03:f0
<output truncated>
switch:admin> nsallshow
{
020f00 021fda 021fdc 021fe0 021fe1
5 Nx_Ports in the Fabric}
switch:admin> switchshow
switchName: rsl8-st03-dcx-01
<output truncated>
switch:admin> fabricshow
Switch ID Worldwide Name Enet IP Addr FC IP Addr Name
<output truncated>
switch:admin>lscfg --show
Created switches: 128(ds) 1 2(bs)
Port
0
1
2
3
-------------------------------------------------------------------
FID
1 | 1 | 1 | 1 | 1 | 128 | 128 | 128 | 128 | 128 |
<output truncated>
switch:admin>
information in the "SANbefor.txt" file created earlier. In particular, look for differences in the
following:
Device types
Number of devices
ISL and port states
Number of switches in the fabric
If there are any mechanical problems, try reseating the associated component.
4
5
6
7
PowerConnect B-DCX-4S Backbone Hardware Reference Manual
8
9
53-1001808-01

Advertisement

Table of Contents
loading

Table of Contents