Dell PowerConnect B-DCX-4S Backbone Hardware Reference Manual page 94

Hardware reference guide
Hide thumbs Also See for PowerConnect B-DCX-4S Backbone:
Table of Contents

Advertisement

5
RRP: PowerConnect B-DCX-4S chassis
2. Enter the slotShow -m command and verify that all the installed cards are detected and that
3. Verify that the PowerConnect B-DCX-4S is functioning correctly by typing switchShow or
4. Verify that all the IP address information is correct by typing ipAddrShow and checking the
80
their status is operational (enabled).
switch:admin> slotShow -m
Slot
Blade Type
ID
--------------------------------------------
1
SW BLADE
51
2
UNKNOWN
3
CORE BLADE 46
4
CP BLADE
50
5
CP BLADE
50
6
CORE BLADE 46
7
AP BLADE
75
8
SW BLADE
51
switch:admin>
switchStatusShow.
This switchShow command displays PowerConnect B-DCX-4S and port status information.
switch:admin> switchshow
switchName:
switch
switchType:
62.1
switchState:
Online
switchMode:
Native
switchRole:
Subordinate
switchDomain:
11
switchId:
fffc0b
switchWwn:
10:00:00:05:1e:39:59:67
zoning:
OFF
switchBeacon:
OFF
blade3 Beacon:
OFF
blade5 Beacon:
OFF
blade8 Beacon:
OFF
blade10Beacon:
OFF
Index
Slot
Port
===========================================================
32
3
0
33
3
1
34
3
2
35
3
3
36
3
4
10:00:00:00:c9:51:00:2d
37
3
5
switch:admin>
results against the IP information recorded in the "config-miscinfo.txt" file.
switch:admin> ipaddrshow
Model Name
Status
FC8-48
ENABLED
VACANT
CR4S-8
ENABLED
CP8
ENABLED
CP8
ENABLED
CR4S-8
ENABLED
FX8-24
ENABLED
FC8-48
ENABLED
Address
Media
Speed
0b2000
id
N4
0b2100
__
N8
0b2200
__
N8
0b2300
__
N8
0b2400
id
N4
0b2500
__
N8
PowerConnect B-DCX-4S Backbone Hardware Reference Manual
State
Proto
Online
L-Port 5 public
No_Module
No_Module
No_Module
Online
F-Port
No_Module
53-1001808-01

Advertisement

Table of Contents
loading