Obtaining Chassis And Component Status; Interpreting Post And Boot Results; Post - Dell PowerConnect B-DCX-4S Backbone Hardware Reference Manual

Hardware reference guide
Hide thumbs Also See for PowerConnect B-DCX-4S Backbone:
Table of Contents

Advertisement

C

Obtaining chassis and component status

Obtaining chassis and component status
The CLI commands in
and its components. These commands provide information only, and they do not interrupt traffic
flow. For more information about these commands, refer to the Fabric OS Command Reference.
TABLE 25
Command
sensorShow
tempShow
psShow
fanShow
chassisShow
slotShow
errShow
errDump

Interpreting POST and boot results

The PowerConnect B-DCX-4S performs Power On Self Test (POST) by default each time the chassis
is powered on, rebooted, or reset. The PowerConnect B-DCX-4S can be rebooted using the reboot
(to reboot each CP individually) or fastBoot commands. The fastBoot command reboots the
switches without running POST. If the active CP blade is rebooted, it fails over to the standby CP
blade.

POST

To verify that POST has completed without error:
106
Table 25
Environmental status and maintenance commands
Information displayed
Temperature readings for the port blades
Temperature readings for the CP blades
Status and RPM of all operational fans
Status of all operational power supplies
Temperature readings for the port blades
Temperature readings for the CP blades
Status of all operational power supplies
Status and RPM of all operational fans
Serial number, time awake, and additional information about each component
Slot occupancy
System error log. Refer to the Fabric OS Message Reference for more information on the
messages in this log.
Verify that all LEDs return to a normal state after POST completes
Components").
If one or more LEDs do not return to a normal state, and this is not due to the PowerConnect
B-DCX-4S being set to beacon, refer to the relevant LED table to identify and correct the
problem. For port blades and CP and core switch blades, the slotShow command can be used
to check the status of the slots. For information about turning beaconing on/off, refer to the
Fabric OS Administrator's Guide.
Verify that the switch prompt displays when POST completes.
If it does not display, POST was not successfully completed. Contact the PowerConnect
B-DCX-4S supplier for support.
Review the system error log using the errShow or errDump commands.
provide status and environmental information about the chassis
PowerConnect B-DCX-4S Backbone Hardware Reference Manual
(Chapter 4, "Monitor System
53-1001808-01

Advertisement

Table of Contents
loading

Table of Contents