Installing Components Into The New Chassis - Dell PowerConnect B-DCX-4S Backbone Hardware Reference Manual

Hardware reference guide
Hide thumbs Also See for PowerConnect B-DCX-4S Backbone:
Table of Contents

Advertisement

5
RRP: PowerConnect B-DCX-4S chassis
NOTE
A fully populated PowerConnect B-DCX-4S (four FC8-48 port cards, 192 ports) weighs approximately
68 kg (150 lbs) and requires a hydraulic or assisted lift to install it.
NOTE
If the PowerConnect B-DCX-4S is installed in a cabinet, ensure that the cabinet is balanced and
secured mechanically and that the removal and installation procedure will not compromise cabinet
stability.
1. If the chassis is in a cabinet, remove it from the cabinet, remove the rack mount hardware, and
2. Place the chassis on a lift or on the shipping pallet provided with the original chassis.
3. Unpack the new chassis:
4. Use a pallet jack or other assisted lift to transport the new chassis to the installation area.
5. Use a lift to raise the chassis to the correct level. If installing the chassis in a cabinet, follow the

Installing components into the new chassis

ATTENTION
Follow ESD precautions
1. Replace the WWN bezel (logo plate) and WWN cards
2. Replace the blower assemblies
3. Replace the power supplies or filler panels
4. Replace the control processor blades (CP8)
5. Replace the core switch blades (CR4S-8)
6. If ICL cables are not used, insert EMI plugs in the ICL sockets in the core switch blades
7.
78
save the hardware for use with the new chassis.
a. Cut the bands that encircle the packaging.
b. Remove the lid and the kits and foam from the top of the chassis.
c.
Lift the cardboard box off the chassis and remove the plastic bag from around the chassis.
Save the packing materials for use when returning the old chassis.
d. Leave the chassis on top of the plastic shipping tray if the chassis must be transported to
the installation location.
NOTE
The PowerConnect B-DCX-4S packaging does not incorporate wood pallet and pallet brackets.
The chassis sits on top of plastic shipping tray.
Doorways must be wider than 91 cm (36 in.) to accommodate the chassis on the pallet.
instructions provided by the rack kit manufacturer.
("ESD
(CR4S-8).
Replace the blades or filler panels
Blade filler
panel").
precautions").
("RRP: Blower
assembly").
("RRP: Power
("RRP: Control processor blade
("RRP: Core switch blade
("RRP: Port, application, and encryption blades"
PowerConnect B-DCX-4S Backbone Hardware Reference Manual
("RRP: WWN
card").
supply").
(CP8)").
(CR4S-8)").
and
"RRP:
53-1001808-01