8. Checking the input voltage
1. Turn on the power switch.
2. Press the menu switch q until the X-SCALE indicator w illuminates.
3. While pressing the TEST switch e, press the R/W switch r.
e
4. If the input voltage is normal, the input voltage conditions will be shown in the display as indicated at right.
Rated voltage: "100"
Allowable voltage range: "090" - "110"
5. Press the TEST switch e once more to return the display to the regular condition.
9. Clearing all memory settings
If the sewing machine stops operating normally, the cause may be that an incorrect memory setting may have been
made by means of the memory switch, for instance. In such cases, carry out the following procedure to clear the
memory, and also check the DIP switch settings.
1. While pressing the R/W switch, turn on the power.
2. When the alarm sounds with a short beep, release the R/W switch.
q ¡
w
BAS-364E, 366E, 370E, 375E
Chapter 7 STANDARD ADJUSTMENTS
r
O N
O F
F
Power switch
40