Appendix A Event Notification Message List
A.2 Message List
Event type
P 1C00MM0p 2
P 1D00MM0p 2
P 1F00MM0p
P 21SSMM00
(When SS is
not 83)
ETERNUS DX80 S2/DX90 S2 Disk storage system User's Guide -Operation-
SNMP Trap
Trap
code
TrapItemID
No.
1C00MM0p
1D00MM0p
2
1F00MM0p
2
2100MM00
Copyright 2012 FUJITSU LIMITED
Upper: Message
Trap
Sensor
Lower: Description
Info
-
FC SFP+ CA Slot#S(zz) (on CM#m) Port#P
Fault <pppppppppppppppp ssssssssssssssss
rrrr oooooooo>
CA SFP+ is disconnected.
SS: Component subtype
MM: CA module ID (40 – 7F)
p: Device port number (0 – 1)
S: CA slot number (0 – 1)
zz: CA type
m: CM number (0 – 1)
P: Port number (0 – 1)
pp...: Component number
ss...: Serial number
rr...: Version
oo...: Additional information
-
iSCSI FCoE SFP+ CA Slot#S(zz) (on CM#m)
Port#P Fault <pppppppppppppppp
ssssssssssssssss rrrr oooooooo>
CA SFP+ is disconnected.
SS: Component subtype
MM: CA module ID (40 – 7F)
p: Device port number (0 – 1)
S: CA slot number (0 – 1)
zz: CA type
m: CM number (0 – 1)
P: Port number (0 – 1)
pp...: Component number
ss...: Serial number
rr...: Version
oo...: Additional information
-
SFP(Type Unknown) CA Slot#S(zz) (on
CM#m) Port#P Fault <pppppppppppppppp
ssssssssssssssss rrrr oooooooo>
CA SFP is disconnected due to an SFP type
that cannot be recognized.
SS: Component subtype
MM: CA module ID (40 – 7F)
p: Device port number (0 – 1)
S: CA slot number (0 – 1)
zz: CA type
m: CM number (0 – 1)
P: Port number (0 – 1)
pp...: Component number
ss...: Serial number
rr...: Version
oo...: Additional information
-
Controller Module#m(zz) FPGA Fault
<pppppppppppp ssssssssssss rrrr>
CM FPGA is disconnected.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (DX80S2 or DX90S2)
pp...: Component number
ss...: Serial number
rr...: Version
109
Remarks
These messages
are notified when
"Parts Error" is
enabled for Error
Severity Level in
the event notifica-
tion setting. They
are not notified
during mainte-
nance operations.
These messages
are notified when
"Parts Error" is
enabled for Error
Severity Level in
the event notifica-
tion setting. They
are not notified
during mainte-
nance operations.
P3AM-4842-03ENZ0