Fujitsu Eternus DX80 S2 User Manual page 121

Disk storage system
Hide thumbs Also See for Eternus DX80 S2:
Table of Contents

Advertisement

Appendix A Event Notification Message List
A.2 Message List
Event type
M E10300xx
M E2070001
M E2070002
M E2070004
M E207000B
M E207000C
M E207000D
M E207000E
M E207000F
M E2070010
M E2070011
M E2070015
ETERNUS DX80 S2/DX90 S2 Disk storage system User's Guide -Operation-
SNMP Trap
Trap
Trap
code
Maintenance
No.
Info
7
E10300xx
7
E2070001
7
E2070002
7
E2070004
7
E207000B
7
E207000C
7
E207000D
7
E207000E
7
E207000F
7
E2070010
7
E2070011
7
E2070015
Copyright 2012 FUJITSU LIMITED
Upper: Message
Lower: Description
PINNED DATA was created CM#m-CPU#v
Pinned Data occurs.
xx: CM module ID in which Pinned Data occurred
m: CM number in which Pinned Data occurred
v: CPU number in CM
NOT READY(01:Configuration Error)
The device is in Not Ready status.
Shipment settings (model setting) and configurations are
not applied.
NOT READY(02:CM F/W Version Error)
The device is in Not Ready status.
Firmware version for the CM is not correct.
NOT READY(04:Restore Fail)
The device is in Not Ready status.
Backup is successfully complete, but the restoration
cannot be performed.
NOT READY(11:Power Off/Fail Incomplete)
The device is in Not Ready status.
Failed to power off. Or the device power turns off
immediately after the device powers on.
NOT READY(12:Backup Fail)
The device is in Not Ready status.
Backup failed.
NOT READY(13:Multi CM Down)
The device is in Not Ready status.
Adjoining CMs with LUs are degraded.
NOT READY(14:Machine Down Recovery End)
The device is in Not Ready status.
Machine down recovery is performed.
NOT READY(15:Machine Down Recovery Failed)
The device is in Not Ready status.
Failed to perform machine down recovery.
NOT READY(16:DE Build Error)
The device is in Not Ready status.
Failed to configure DE because of QSFP cable errors or
FC cable errors.
NOT READY(17:CM Memory Shortage)
The device is in Not Ready status.
Memory capacities are smaller than the minimum value in
multiple CMs.
NOT READY(21:Auto CFD)
The device is in Not Ready status.
Automatic CFD is performed.
121
Remarks
These mes-
sages are noti-
fied when
"Pinned data" is
enabled for Error
Severity Level in
the event notifi-
cation setting.
They are not noti-
fied during main-
tenance
operations.
These messages
are notified when
"Not ready" is
enabled for Error
Severity Level in
the event
notification
setting. They are
not notified
during
maintenance
operations.
P3AM-4842-03ENZ0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eternus dx90 s2

Table of Contents