Appendix A Event Notification Message List
A.2 Message List
Sense code
SK
04
04
04
04
04
04
04
04
04
04
04
04
04
04
04
04
04
04
04
04
04
04
04
04
04
06
06
06
06
ETERNUS DX80 S2/DX90 S2 Disk storage system User's Guide -Operation-
ASC
ASCQ
F1
80
3.5" HDD is disconnected.
F1
81
2.5" HDD is disconnected.
F1
84
3.5" SSD is disconnected.
F1
85
2.5" SSD is disconnected.
F1
88
Drive is disconnected because an error occurred dur-
ing the Write check of the disk patrol.
F1
90
IOM is disconnected.
F1
91
IOM Port is disconnected.
F1
9A
IOM QSFP is disconnected.
F1
D2
DPSU is disconnected.
F1
DA
CE or DE exhaust temperature error is detected.
F1
DB
CE or DE intake temperature error (sensor failure) is
detected.
F2
02
CM DMA Port is disconnected.
F2
03
CM BIOS is disconnected.
F2
04
CM RTC is disconnected.
F2
05
CM NVRAM is disconnected.
F2
06
CM EXP is disconnected.
F2
08
CM DI Port is disconnected.
F2
09
CM EXP IN port is disconnected.
F2
0A
CM EXP Out port is disconnected.
F2
0E
CM NAND Controller is disconnected.
F2
0F
CM SCU is disconnected.
F2
11
CA port is disconnected.
F2
21
CM FPGA is disconnected.
F2
22
CM LAN Port is disconnected.
F8
00
Pinned Data occurs.
11
90
Writing of Bad Data (data lost identifier) occurs.
C1
01
CM is rebooted.
C1
10
CA is rebooted.
C1
90
IOM is rebooted.
Copyright 2012 FUJITSU LIMITED
Description
139
Remarks
These sense codes are notified when
"Disk Error" is enabled for Error
Severity Level in the event notification
setting.
They are not notified during mainte-
nance operations.
These sense codes are notified when
"Parts Error" is enabled for Error
Severity Level in the event notification
setting.
They are not notified during mainte-
nance operations.
This sense code is notified when
"Temperature Error" or "Parts Error" is
enabled for Error Severity Level in the
event notification setting.
This is not notified during mainte-
nance operations.
These sense codes are notified when
"Parts Error" is enabled for Error
Severity Level in the event notification
setting.
They are not notified during mainte-
nance operations.
This sense code is notified when
"Pinned data" is enabled for Error
Severity Level in the event notification
setting.
This is not notified during mainte-
nance operations.
This sense code is notified when "Bad
data" is enabled for Error Severity
Level in the event notification setting.
This is not notified during mainte-
nance operations.
These messages are notified when
"Remote Path Error" is enabled for
Warning Level in the event notification
setting.
They are not notified during mainte-
nance operations.
P3AM-4842-03ENZ0