Appendix A Event Notification Message List
A.2 Message List
Event type
M A0C10xxx
M A1410xxx
M A1810xxx
M A1A10xxx
M A1B10xxx
M A1C10xxx
M A3420xxx
M A3820xxx
ETERNUS DX80 S2/DX90 S2 Disk storage system User's Guide -Operation-
SNMP Trap
Trap
Trap
code
Maintenance
No.
Info
7
A0C10xxx
7
A1410xxx
7
A1810xxx
7
A1A10xxx
7
A1B10xxx
7
A1C10xxx
7
A3420xxx
7
A3820xxx
Copyright 2012 FUJITSU LIMITED
Upper: Message
Lower: Description
RAID Group#0xxx retry procedure of Rebuild processing
Rebuild to the hot spare is retried.
xxx: RAID group number (hexadecimal)
RAID Group#0xxx start procedure of Rebuild processing
Rebuild to the replaced drive has started.
xxx: RAID group number (hexadecimal)
RAID Group#0xxx normal end of Rebuild processing
Rebuild to the replaced drive is complete.
xxx: RAID group number (hexadecimal)
RAID Group#0xxx abnormal end of Rebuild processing
because of source disk problem
Rebuild to the replaced drive is halted because an error is
found in the copy source drive.
xxx: RAID group number (hexadecimal)
RAID Group#0xxx abnormal end of Rebuild processing
Rebuild to the replaced drive is abnormally ended.
xxx: RAID group number (hexadecimal)
RAID Group#0xxx retry procedure of Rebuild processing
Rebuild to the replaced drive is retried.
xxx: RAID group number (hexadecimal)
RAID Group#0xxx start procedure of Copyback
processing
Copyback to the replaced drive is being performed.
xxx: RAID group number (hexadecimal)
RAID Group#0xxx normal end of Copyback processing
Copyback to the replaced drive is complete.
xxx: RAID group number (hexadecimal)
119
Remarks
These mes-
sages are noti-
fied when
"Rebuild/
Copyback w/o
redundant" is
enabled for Error
Severity Level in
the event notifi-
cation setting.
They are not noti-
fied during main-
tenance
operations.
These mes-
sages are noti-
fied when
"Rebuild/
Copyback w/
redundant" is
enabled for Error
Severity Level in
the event notifi-
cation setting.
They are not noti-
fied during main-
tenance
operations.
These mes-
sages are noti-
fied when
"Rebuild/
Copyback w/o
redundant" is
enabled for Error
Severity Level in
the event notifi-
cation setting.
They are not noti-
fied during main-
tenance
operations.
These mes-
sages are noti-
fied when
"Rebuild/
Copyback w/
redundant" is
enabled for Error
Severity Level in
the event notifi-
cation setting.
They are not noti-
fied during main-
tenance
operations.