Chapter 12: Parameters

This chapter describes the parameters that can be set in the module. The parameter area is set in the
control module (CPU board).

12-1 Table of parameters

Address
(8)
00
IP address
01
IP address
02
IP address
03
IP address, node number
04
Token monitor timing => See next page
05
Interval between frames (normally set to 0)
06 to 07
Reserved area
10
Data transmission Area 1 top address (word address) for this node.
- Address 10 is for the lower digit. Address 11 is for the upper digit.
11
12
Data length (word) of Area 1 for this node.
- Address 12 is for the lower digit. Address 13 is for the upper digit.
13
14
Data transmission Area 2 top address (word address) for this node.
- Address 14 is for the lower digit. Address 15 is for the upper digit.
15
16
Data length (word) of Area 2 for this node.
- Address 16 is for the lower digit. Address 17 is for the upper digit.
17
20
Top address of Area 1 on the PC (word address)
- Address 20 is for the lower digit. Address 21 is for the upper digit.
21
22
Area 1 file number on the PC
23
Reserved area
24
Top address of Area 2 on the PC (word address)
- Address 24 is for the lower digit. Address 25 is for the upper digit.
25
26
Area 2 file number on the PC
27
Reserved area
Top address of the communication control area on the PC (word
30
address)
31
- Address 30 is for the lower digit. Address 31 is for the upper digit.
32
Communication control area's file number on the PC
Communication control area transfer type
- Specify the address to transfer from the module to the control
module (CPU board)
00
: Transfer all of the area
(H)
33
80
: Does not transfer data from the communication transfer area.
(H)
81
: Transfer only the participating node list flag, operation status
(H)
flag, and error status flag.
83
: Transfer all of the area.
(H)
34
Transmission buffer top address (word address)
- Address 34 is for the lower digit. Address 35 is for the upper digit.
35
36
Transmission buffer file number
37
Enable/disable use of the transmission buffer => See next page
40 to 51
Node name (10 ASCII characters)
52 to 57
Reserved area
60
Timeout time for the SEND/RECEIVE instruction (0.1 to 25.5 sec.).
61 to 76
Reserved area
Start switch
77
- When the value of this switch changes from 00 to 01
settings are transferred to the module.
- Do not write data in the reserved areas (5 locations).
When the JW-50FL is used, set the parameters in system memory.
"12-3 How to set parameters."
Details
When FF
is written to address 03, the module will
(H)
enter the data memory setting mode.
- Enter the parameter file address at addresses
00 and 01. Enter the file number at address 02.
, the parameters
(H)
12-1
Chapter 12: Parameters
Reference
page
7-5
7-8
12-3
15-13
8-13
15-22
-
Related to
cyclic
Chapter 8
transfers
-
Related to
communi-
Chapter 10
cation
control
Related to
message
Chapter 9
transfer
-
-
11-8
-
8-3
9-2
See pages 12-4 to 12-5.