Connection Of Jw-50Fl - Sharp JW-20FL5 User Manual

Fl-net module (board)
Table of Contents

Advertisement

Chapter 6: Connection/Wiring

[4] Connection of JW-50FL

(1) Connection of 10BASE5
This paragraph describes how to connect 10BASE5 cable to the JW-50FL.
Connecting the transceiver cable
6
1 Slide the lock on the 10BASE5 connector (on the JW-50FL) up.
2 Insert the connector so that the two locking posts on the cable connector match the holes on
the slide lock.
3 Slide the lock down to lock the cable connector.
Wiring the power source
When a 10BASE5 is used, 12 VDC power should be supplied to the transceiver.
Supply power to the 12 VDC power terminals using a commercial constant voltage power supply
unit.
Supply voltage
Current capacity
Remarks
- Use a power supply that is dedicated for use by the JW-50FL.
- Do not reverse the positive and negative connections to the power terminals. Reversing the
polarity may damage the JW-50FL.
Locking post
Locking post
Transceiver cable
Item
Specifications
12 VDC –5%
0.5 A minimum.
* Fuse (0.6 A)
12 VDC
* Use a fuse melt with time lag
Black wire (-)
Red wire (+)
Twisted pair wires
Case
Cable
(Accessory: Connector, cable length 1.5 m)
6-8
Slide lock
10BASE5 connector
Green wire
(ground)

Advertisement