Outside Line Programming
4 6 0
Description
Selection
Default
Programming
Conditions
Feature References
Disconnect Time
Determines the amount of time between successive accesses to the
same outside line.
Outside line (CO) number: 1 through 3, * ( * =all outside lines)
l
Time (seconds): 1.5 / 4.0
l
Time (seconds): 1.5 / 4.0
l
All outside lines - 1.5 s
1.
Enter 414.
Display: 414 DISCONNECT
2.
Press NEXT.
Display: CO Line NO?+
3.
Enter an outside line number.
To program outside line number 1, you can also press
Display example: CO1:1.5sec
4.
Keep pressing SELECT until the desired time is displayed.
5.
Press STORE.
To program another outside line, press NEXT or PREV, or
6.
SELECT and the desired outside line number.
Repeat steps 4 through 6.
8.
Press END.
The disconnect time must be longer than the requirements of the central
l
To assign all outside lines to one selection, press the * key in step 3.
l
In this case, the display shows the contents programmed for outside line
1.
Section 3, Features
Flash
4 1 4
NEXT.
System Programming
4-107