CHAPTER 2 DEPENDENCE FUNCTIONS
■ Displaying and Setting External Probe Data
When a command that can use external probe data is executed, external probe data is displayed in 8-digit
binary or 2-digit hexadecimal format. The displayed bit order is in the order of the IC clip cable color code
order (Table 2.2-12). The MSB is at bit7 (Violet), and the LSB is at bit0 (Black). The bit represented by 1
means HIGH, while the bit represented by 0 means LOW. When data is input as command parameters, these
values are also used for input.
Table 2.2-12 Bit Order of External Probe Data
IC Clip
Cable Color
Bit Order
■ Commands for External Probe Data
Table 2.2-13 shows the commands that can be used to set or display external probe data.
Table 2.2-13 Commands that can be used External Probe Data
Usable Command
SET SAMPLING
SHOW SAMPLING
SET EVENT
SHOW EVENT
SHOW TRACE
SHOW MULTITRACE
134
Violet
Blue
Green
Bit 7
Bit 6
Bit 5
Sets sampling timing for external probe
Samples external probe data
Enables to specify external probe data as condition for event
Displays event setup status
Displays external probe trace-sampled (single trace)
Displays external probe trace-sampled (multi-trace)
Yellow
Orange
Red
Bit 4
Bit 3
Bit 2
External probe data
Function
Brown
Black
Bit 1
Bit 0