CHAPTER 2 DEPENDENCE FUNCTIONS
Indicates
that, if event
1 occurs at
level 1, move
to level 2 and
let the timer
latched.
104
>SET SEQUENCE/EVENT
1,1,J=2
>SET SEQUENCE/EVENT
2,4,J=1
>SET SEQUENCE/EVENT
2,2,J=3
>SET SEQUENCE/EVENT
3,4,J=1
>SET SEQUENCE/EVENT
3,2,J=0
>SET SEQUENCE/LATCH
1,1,2
>SET SEQUENCE/LATCH
2,3,0
>SHOW SEQUENCE
Sequencer Enable
level1
level2
level3
1 |1|#>2
| |
| |
2 | |
|2|->3
| |
3 | |
| |
|3|#end
4 | |
|4|->1
|4|->1
5 | |
| |
| |
6 | |
| |
| |
7 | |
| |
| |
8 | |
| |
| |
T | |
|T|->1
| |
Latch 1 (1->2) = 00m02s060ms379.0μs
Indicate time values of timer latch 1 and timer latch 2. The time
value, deducting the value of the timer latch 1 from the value of the
timer latch 2, represents the execution time.
Time is displayed in the following format.
00 m 00 s 000 ms 000.0 μs
minutes
seconds
milliseconds
Indicates that, if event 3
occurs at level 3, the
sequencer terminates and
let the timer latched.
level4
level5
level6
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
Latch 2 (3->E) = 00m16s040ms650.0μs