2 - 22 MC3000 Integrator Guide
UBC Adapter Charge LED Status Indications
Table 2-3
LED
STANDBY or
Flashing-Yellow
FAULT
Yellow
CHARGING
Yellow
Indication
The battery was deeply discharged and is being trickle charged to bring the
voltage up to the operating level. After operating level voltage is achieved, the
battery charges normally.
Charging error, check placement of mobile computer/spare battery.
Normal charge.
Description