NEC Express5800 1160Xd User Manual page 87

Hide thumbs Also See for Express5800 1160Xd:
Table of Contents

Advertisement

Table 3-31. EN Screen References (cont'd)
Reference
Description
C
When you press ENTER, the next page is displayed
D
Displays an alarm state for the DCDC converter on the CELL Board/XBC Board in
the CPU/Memory Sub-chassis (16-way)/(32-way) in the Main Cabinet.
If an alarm occurs, an asterisk (*) mark appears at the beginning of the line.
E
Displays an alarm state for the DCDC converter/fan/temperature of the Full/Half-size
PCIX Unit.
If an alarm occurs, an asterisk (*) mark appears at the beginning of the line.
F
Displays the temperature detected by the board/unit temperature sensor.
If an alarm occurs, an asterisk (*) mark appears at the beginning of the line.
Also displays the threshold values hard-coded in iSPFW.
"FAN" indicates the threshold values for high-speed and low-speed fan rotation.
"IPMI" indicates the threshold values at which a report is sent to the software via the
IPMI interface.
" ACPI " indicates the threshold values at which a report is sent to the software via
the ACPI interface.
Service Processor 3-31