Changing The Coolant - Komatsu PC27R-8 Operation & Maintenance Manual

Hydraulic excavator
Hide thumbs Also See for PC27R-8:
Table of Contents

Advertisement

MAINTENANCE PLAN
4.7.11.b CHANGING THE COOLANT
DANGER
Soon after the machine has been stopped the coolant is
very hot and under pressure and it may cause serious
burns; let the engine cool down until it reaches approxi-
mately 40÷45°C before changing the coolant.
Slowly loosen the radiator cap, in order to release the re-
sidual pressure.
Oils, filters, the coolant and the battery are considered
special waste and must be collected and disposed of ac-
cording to the anti-pollution regulations in force.
IMPORTANT
The following operations refer to the change of permanent
coolants; if the coolant is water or water with antifreeze,
which is used according to the season, it is necessary to
wash the cooling circuit in order to eliminate any encrus-
tation. (See "4.7.1.a WASHING THE COOLING CIRCUIT").
1 - Open the engine hood (See "3.5.1 ENGINE HOOD").
2 - Rotate the right counterweight to the open position (see
"3.5.2 RIGHT COUNTERWEIGHT").
3 - Loosen and remove the upper cap (1) of the radiator.
4 - Open the drain cock (2) of the radiator, remove the drain plug
(3) positioned on the engine block and let the fluid flow out.
Use a 17 mm hexagon spanner.
While the fluid flows out, drain the coolant tank (4).
5 - Close the drain cock (2), put back the plug (3) on the engine
block and fill the radiator with new fluid (See "4.3 FUEL,
COOLANT AND LUBRICANTS").
6 - Start the engine and let it idle for a few minutes; check the
level again and if necessary top up before putting back the
upper cap (1).
7 - Fill the tank (4) until reaching the maximum level.
8 - Rotate the lateral counterweight to the closed position, close
the engine hood and put back the inspection cover (1)
168