13 Configure the alarm settings [Alarm]
Alarm input: Receives alarms.
AUX output: AUX output will be supplied. The [AUX] buttons will be displayed on the "Live" page.
Default: Off
Note
AUX is a camera terminal that allows users to operate (Open/Close) arbitrarily from the "Live" page.
For example, an operator can remotely control lights in a place where the camera is installed by
connecting the terminal to the light controller.
Refer to the installation guide for further information about input/output rating of each terminal.
While "Alarm input" is being selected, an alarm is detected when the terminal status is changed to
"On". (Default)
It is possible to configure the setting so that an alarm is detected when the terminal status is changed
to "Off". Refer to the [Readme] file on the provided CD-ROM for further information about the setting.
Or refer to our website (http://panasonic.net/pss/security/support/info.html) for further information
about the supported software.
[VMD alarm]
When clicking "VMD >>", the [VMD area] tab of the "Alarm" page will be displayed. (®page 137)
[Auto track alarm]
When clicking "Auto track setting >>", the [Image/Position] tab of the "Camera" page will be displayed. The
setup menu will be displayed in a newly opened window. (®page 115)
[Command alarm]
Select "On" or "Off" to determine whether or not to receive the command alarm.
The command alarm is the function that provides notification of a Panasonic protocol alarm from the other
cameras. When "On" is selected, alarm actions will be performed between multiple cameras.
Default: Off
[Originating port number]
Select a port number to be used to receive the command alarm.
Available range: 1-65535
Default: 8181
The following port numbers are unavailable since they are already in use.
20, 21, 23, 25, 42, 53, 67, 68, 69, 80, 110, 123, 161, 162, 443, 554, 995, 10669, 10670, 59000-61000
13.2 Configure the settings relating to the camera
action on alarm occurrence [Alarm]
Click the [Alarm] tab on the "Alarm" page. (®page 43, page 45)