DS7200V2-EXP | Installation Guide | 4. Reference Materials
Miscellaneous Issues
Problem
There are numbers in
braces {###} throughout
this manual.
My printer is printing
strange characters and I
cannot read it.
Network communication is
not working as expected.
4.3
Data Bus Address Quick Reference
Table 41:
Data Bus Address Quick Reference
Data Bus Address
0
1 to 8
40, 41
50
51
52 to 55
60 to 63
101 to 107
134
150, 151
250
Bosch Security Systems, Inc. | 04/12 | F01U253045-02
Cause
These numbers {###} refer to the
event numbers described Control
Panel Events and Reporting Formats
on page 108.
The settings for the DX4010 RS-
232 Serial Interface Module can
cause unexpected printer output.
•
The DX4020 Network Interface
Module is not properly wired
and/or configured.
•
The control panel is not
properly programmed for
network communication.
Device Description
Installer Keypad or local connection to RPS
Keypads 1 to 8
DX8010 Telephone Control Module
Premises RF Receiver 1
Premises RF Receiver 2
Premises RF Keypads Receiver 1
Premises RF Keypads Receiver 2
DX2010 Wired Input Expanders
DX4020 Network Interface Module (NIM)
DX3010 Output Expanders and/or DX3020 X-10 Interface Module
DX4010i/DX4010 Serial RS-232 Interface Module
Solution
N/A
Verify the settings for the following parameters
(see the DS7200V2 Expert Programming Guide
P/N:4998153891):
•
"DX4010 Output Configuration" (Address
1253)
•
"Baud Rate Configuration" (Address 1254)
•
"Parity/Flow Control/Stop Bit
Configuration" (Address 1255).
•
Make sure the DX4020 is properly
connected to the control panel. See
DX4020 Wiring on page 37.
•
Make sure the DX4020's DIP switches are
set to Address 134 (see DX4020
Addressing on page 36).
•
Make sure your selection for Address 3541
includes the "Alternate Communication
Interface at Address 134" option. See
Network Interface Module Options on page
105.
•
See the DX4020 Installation Guide
(P/N: 49522) for additional configuration
requirements.
•
Make sure you are using a valid IP address
and that you entered it correctly. See IP
Address 1 (2) for Destination 1 (2) on page
101.
•
Make sure selection for Alternate
Communication Options (see page 102)
includes the "Enable Alternate
Communication" option.
EN | 122