DS7200V2-EXP | Installation Guide | 2. System Installation
and Setup
2.9
Network Interface Module
(DX4020)
Firmware revision 2.10 or greater is
required to use the DX4020.
2.9.1
DX4020 Overview
The DX4020 Network Interface Module (NIM)
provides bi-directional communication over an
Ethernet network. It can also be used for remote
programming sessions with RPS.
2.9.2
DX4020 Addressing
Set the DIP Switch address to 134 when using
the DX4020 for network communication.
Figure 53:
Network Communication DIP
Switch Setting
1- OPEN (UP) position
2- CLOSED (DOWN) position
Sample address setting shown is for Address
134
Bosch Security Systems, Inc. | 04/12 | F01U253045-02
2.9.3
DX4020 Installation
Failure to follow the mounting
instructions in this document can
result in damage to the module.
The DX4020 contains static-sensitive
components and must be handled
with care. Follow anti-static
procedures when handling this
module.
Mount the DX4020 to the back wall of the control
panel's enclosure (see Figure 54), or to the
interior side walls of the control panel's
enclosure (see Figure 55).
Figure 54:
Standard DX4020 Mounting
Locations
1
2
1- Control panel board location
2- Standard DX4020 mounting locations
3- DX4020 module
4- Enclosure wall
Screws (supplied with DX4020)
Figure 55:
Optional DX4020 Mounting
Locations
1
5
2
1- Control panel board location
2- Optional DX4020 mounting location
EN | 36