3.10.3

Adjustment of skew

When an image skew occurs, adjust it according to the following steps, Step 1 → Step 2 → Step 3.
Note:
Note:
Perform this adjustment after confirming that the equipment has been adjusted properly.
Prior to this adjustment, of RADF position and height are needed to be adjusted.
(1)
Step 1
Case A: ................Adjust the aligning adjustment position to the rear side "-" of the original
Case B: ................Adjust the aligning adjustment position to the rear side "+" of the original
A
(2)
Step 2
Case C: ................Loosen the fixing screw and hand screw of the right side hinge and then turn
Case D: ................Loosen the fixing screw and hand screw of the right side hinge and then turn
Note:
Note:
When adjusting, refer to the hinge position (scribed line) and be sure not to move it from the
hinge position ±0.5 mm or further. Otherwise, image failures such as a jitter may occur.
C
Paper
Original
Fig. 3-71
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
(Chap. 3.10.5).
(Chap. 3.10.5).
Paper
Original
Fig. 3-70
the adjustment screw counterclockwise.
the adjustment screw clockwise.
D
3 - 59
04/05
B
White arrow: feeding direction
Fixing screw
Adjustment screw
Hand screw
RADF
Front side
Fig. 3-72