2.2.4
Test print mode (test mode 04)
The embedded test pattern can be printed out by keying in the following codes in the test print mode (04).
<Operation procedure>
[0][4]
(Code)
[POWER]
Notes:
1. When an error occurs, it is indicated on the panel, but the recovery operation is not per-
formed. Turn OFF the power and then back ON to clear the error.
2. During test printing, the [CLEAR] button is disabled when "Wait adding toner" is displayed.
Code
Types of test pattern
111
Primary scanning direction 33 gradation steps
113
Secondary scanning direction 33 gradation steps Error diffusion
142
Grid pattern
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
[START]
Operation
Continuous
Test Printing
2 - 45
05/12
[CLEAR]
[POWER] OFF/ON
(Exit)
Remarks
Error diffusion
Pattern width: 2 dots, Pitch: 10 mm