3.12.4
Adjusting the tension of the stack processing motor belt
(1)
Remove the right inner cover and the rear cover.
(2)
Remove the 2 mounting screws, and detach the grip unit.
(3)
Loosen the screw on the tension arm plate. (The tension arm plate will be pulled under tension
by the tension spring.)
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Grip unit
Screw
Fig. 3-122
Screw
Tension arm plate
Fig. 3-123
3 - 87
Screw
e-STUDIO350/352/353/450/452/453
ADJUSTMENT
3