Issue 13.0
Power Off for Power Save Group 2
1.
Press Speaker and dial (Service Code 731).
2.
Dial 02, Group 2
3.
Dial 1, Power Off
4.
Enter the Password (Default: 0000)
Power supply to the system is cut when all terminals of Power Save group 2 are in an Idle state.
Password is set in Program 90-02-02 (User ID3).
5.
Press Speaker to set Power Off for Power Save Group 2.
Power On for Power Save Group 2
1.
Press Speaker and dial (Service Code 731).
2.
Dial 02, Group 2
3.
Dial 0, Power On
4.
Press Speaker to set Power On for Power Save Group 2.
Power Off for the Entire Power Save Group
1.
Press Speaker and dial (Service Code 731).
2.
Dial 00, Entire Group
3.
Dial 1, Power Off
4.
Enter the Password (Default: 0000)
Power supply to the system is cut when all terminals of Entire Power Save Group are in an Idle state.
Password is set in Program 90-02-02 (User ID3).
5.
Press Speaker to set Power Off for Entire Power Save Group.
Power On for the Entire Power Save Group
1.
Press Speaker and dial (Service Code 731).
2.
Dial 00, Entire Group
3.
Dial 0, Power On
4.
Press Speaker to set Power On for Entire Power Save Group.