RWIU System Installation
RWIU Additional Information
Ring Back Tones Generator
The RWIU PCB incorporates a 32KB EPROM that generates:
o
440 Hz ring back tone, modulated at 480 Hz
o
2400 Hz busy override tone
o
4 tone channels for the U.S.
Each tone generates 800 bytes every 125 ms. The bytes are sent on a specific time slot of the
matrix and to the related time slot of the PHIN output.
Serial Line Interface
There is a six-pin serial line interface (J7) that debugs and sets up the system. It is a RS-232 port
and connects the PC to the RWIU (see
Table 21
Connector J7 Descriptions
Pin No.
Software Architecture
The RWIU software is a real-time embedded software, written in C language designed for the Intel
80186EC processor. Its modules include real-time tasks, service packages, and hardware drivers.
Its functions are:
o
Communication (KSU DHWY and Base Station)
o
Local debugging
o
Monitor communication
o
Call control logic procedures (call origination, delivery and release)
Mobility control (handoff)
o
o
Handset text and icon displays
o
System and Base Station power up controls
o
RWIU cross connects
Base Station software download
o
o
Start-up diagnostics (BIT)
o
Online diagnostics
o
Loop tests
o
System audit and parameter refresh
o
RWIU and Base Station configuration
o
Alarm reports and LEDs
64
Name
1
TXD
2
RTS_0
3
RXD
4
CTS_1
5
6
GND
Table
21).
Description
RS-232 TX data (from the RWIU)
RS-232 RTS data (from the RWIU)
RS-232 RX data (to the RWIU)
RS-232 CTS data (from the RWIU)
Not used