Installation - Motorola 7545MBW User Manual

Omnii hand-held computer
Table of Contents

Advertisement

4 - 26 Omnii Hand-Held with Windows CE 6.0 User Manual
ST3006 Battery Charger
Figure 4-22

Installation

The charger can be wall mounted using the wall mount kit (MT2031) or it can be operated on a flat surface.
Install the charger in an area that is free from excessive dirt, dust and contaminants. The ambient temperature
must be in the range 5°C to 39°C (41°F to 102°F). The charger will not charge batteries outside of this temper-
ature range. For maximum performance, it is recommended that the charger be operated at room temperature
— a temperature range between 18°C to 25°C (64°F to 77°F).
The charger can consume up to 6 A at 120 VAC, 3A at 240 VAC. Check to ensure the mains circuit supplying
the charger is adequate for this loading (especially if several chargers are being powered from the same
circuit). After unpacking the unit:
Visually check the charger for damage.
Install the IEC power cord and apply power.
IMPORTANT
All charge indicators flash momentarily at power up to indicate that the charger is ready for operation.
Charging bay (6)
Drain holes (6)
Use IEC-320 C13 power cords approved by Motorola, with the ground pin
connected to a proper earth-grounded receptacle. Check with a qualified
electrician if you are uncertain of your receptacle grounding.
TOP
Charger indicator LEDs (4 per bay)
BOTTOM
Rubber feet (5)
DC IN connector
Bracket mounting holes (2)