Chapter 5 Host Interface Management
5.2 Modify Port Parameters
5.2.2

Modify iSCSI Port Parameters

This function sets the parameters for the iSCSI host interface port that connects between the ETERNUS DX and
the host, or connects between the storage systems for REC.
When changing port parameters during operation, stop access from the server that is allocated to the target
port. Host access does not need to be stopped to change the port parameters of newly added CA ports.
The procedure to set iSCSI port parameters is as follows:
Procedure
1
Select which iSCSI port to set the parameters for (multiple selections can be made) and click
[Configure iSCSI Port] in [Action].
 The [Modify iSCSI Port Parameters] screen appears.
Multiple "1G iSCSI" or "10G iSCSI" type iSCSI ports with the same port mode can be selected.
Multiple ports can be set with the same or with different parameters in a single operation. To set
parameters to multiple ports, select the target ports and specify the parameters for each port.
After the specification is complete, click the [Modify] button.