Reset Button (Rst); Fibre Channel Storage Ports - Hitachi 3080 G2 Hardware Reference Manual

Hitachi nas platform
Hide thumbs Also See for 3080 G2:
Table of Contents

Advertisement

When power cables are connected to the PSUs, the server normally powers
up immediately. If, after 10 seconds, the LEDs on the power supplies are lit,
but the Power Status LED is not lit, press the PWR button to restore power to
the system. Open a case with the Hitachi Data Systems Support Center to
get the problem resolved.
Note: Do not use the power button during normal operation of the server.
Pressing the power button immediately causes an improper shutdown of the
system. The PSUs will continue to run.

Reset button (RST)

The reset button has several functions.
• Pressing the reset button when the server is powered on causes a hard
• Pressing the reset button for more than five seconds when the server is
Caution: If the server is non-responsive, see
server on page
not produce a dump.

Fibre channel storage ports

The Fibre Channel (FC) storage ports allow you to connect the server with
other FC devices, such as storage subsystems.
FC ports operate at speeds of two to eight (8) gigabits per second. FC ports
use an enhanced small form factor pluggable (SFP+) optical connector.
The SFP+ ports can be removed from the chassis.
Note: When removed, the 10 GbE and 8 GB Fibre Channel (FC) SFP+ storage
ports are indistinguishable from one another except for their part numbers.
The part number is located on the side of the port housing and is only visible
when the port is removed. Part number prefixes are different as follows:
• 10 GbE: FTLX<number>
• FC: FTLF<number>
50
reset of the server.
This reset occurs after a 30-second delay, during which the server status
LED flashes rapidly and the server attempts to shut down properly. Even
with the delay, pressing the reset button does not guarantee a complete
shutdown before rebooting. Only press the reset button when the server is
powered on to recover a server which has become unresponsive. Pressing
the reset button at this time may produce a dump automatically.
not powered up disables the NVRAM battery pack (which may be
necessary prior to shipping if an incomplete shutdown occurred.) See
Powering down the server for shipment or storage on page 85
information.
83. Do not pull the power cord. Pulling the power cord does
Hitachi NAS Platform server components
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
for more
Restarting an unresponsive

Hide quick links: