LG SV-iS5 Instruction Manual page 131

Variable frequency drives
Hide thumbs Also See for SV-iS5:
Table of Contents

Advertisement

[Hold step]
This is used to hold the last step frequency in Auto-A
operation.
Related Functions:
I/O-51 ~ I/O-84 [Sequence Operation]
Output Frequency
Sequence 1
SEQ1 / 2F
SEQ2 / 2F
SEQ1 / 1F
SEQ3 / 2F
SEQ3 / 1F
P1-CM
ON
' SEQ-L'
P2-CM
' SEQ-M'
P3-CM
ON
ON
ON
' Go step'
[' Go step' in Auto-B Operation]
Output Frequency
Sequence 1
SEQ2 / 2F
SEQ1 / 2F
SEQ2 / 1F
SEQ1 / 1F
P1-CM
ON
' SEQ-L'
P2-CM
' SEQ-M'
P3-CM
ON
' Hold step'
[' Hold step' in Auto-A Operation]
Morek IT OÜ, Rauna 24, 76506 Saue Harjumaa, Estonia. www.morek.eu Tel. +372 604 1423 Fax +372 604 1447 morek@morek.eu
Sequence 3
Sequence 2
ON
ON
ON
Minimum 100msec
Sequence 2
ON
Chapter 6 - Parameter Description [I/O]
[Trv Off.Lo]
This function is used to make negative offset during
traverse operation.
Related Functions:
[Trv Off.Hi]
This function is used to make positive offset during
traverse operation.
Related Functions:
[Interlock1, 2, 3, 4]
Time
This function is used for MMC operation. Refer to MMC
operation.
Related Functions:
[Reset]
Time
This function is set to use it as fault reset terminal when
ON.
Time
[BX]
This function is set to use it as Emergency Stop terminal
Time
when ON.
[JOG]
This function is set to use Jog operation terminal when
ON.
[FX]
This function is set to issue Forward Run.
[RX]
This function is set to issue Reverse Run.
Time
[Ana Change]
Inverter changes its frequency reference source from V1
to I when ON.
Time
[Pre excite]
This setting switches the inverter in pre-exciting state
Time
when assignning Pre excite to the desired terminal. This
function applies only the exciting current to a motor in
Time
Sensorless_S control. In Vector_SPD control, the
inverter conducts pre-exciting to start a motor after the
magnetic -flux is established and holding torque, even
200% of motor nominal torque is guaranteed. When the
operation command is set to ON, the state changes from
pre-exciting to normal.
125
APP-06 ~ APP-07 [Traverse Offset]
APP-06 ~ APP-07 [Traverse Offset]
APP-29 [Inter-Lock Selection]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents